Effect of contact area on the wear of ultrahigh molecular weight polyethylene in noncyclic pin-on-disk tests

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.author Saikko, Vesa
dc.date.accessioned 2019-10-30T10:01:43Z
dc.date.available 2019-10-30T10:01:43Z
dc.date.issued 2017
dc.identifier.citation Saikko, Vesa. 2017. Effect of contact area on the wear of ultrahigh molecular weight polyethylene in noncyclic pin-on-disk tests. Tribology International. Volume 114. 84-87. ISSN 0301-679X (printed). DOI: 10.1016/j.triboint.2017.04.020. en
dc.identifier.issn 0301-679X (printed)
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/40964
dc.format.extent 84-87
dc.format.mimetype application/pdf en
dc.language.iso en en
dc.publisher Elsevier BV en
dc.relation.ispartofseries Tribology International en
dc.relation.ispartofseries Volume 114
dc.rights © 2017 Elsevier BV. This is the post print version of the following article: Saikko, Vesa. 2017. Effect of contact area on the wear of ultrahigh molecular weight polyethylene in noncyclic pin-on-disk tests. Tribology International. Volume 114. 84-87. ISSN 0301-679X (printed). DOI: 10.1016/j.triboint.2017.04.020, which has been published in final form at http://www.sciencedirect.com/science/article/pii/S0301679X17301834. This post-print is published with permission from Elsevier under CC BY-NC-ND 4.0 license (http://creativecommons.org/licenses/by-nc-nd/4.0/). en
dc.subject.other Mechanical engineering en
dc.title Effect of contact area on the wear of ultrahigh molecular weight polyethylene in noncyclic pin-on-disk tests en
dc.type A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä fi
dc.description.version Peer reviewed en
dc.rights.holder Elsevier BV
dc.contributor.school Insinööritieteiden korkeakoulu fi
dc.contributor.school School of Engineering en
dc.contributor.department Konetekniikan laitos fi
dc.contributor.department Department of Mechanical Engineering en
dc.subject.keyword biotribology en
dc.subject.keyword prosthetic joint en
dc.subject.keyword noncyclic pin-on-disk en
dc.subject.keyword UHMWPE en
dc.identifier.urn URN:NBN:fi:aalto-201704193608
dc.type.dcmitype text en
dc.identifier.doi 10.1016/j.triboint.2017.04.020
dc.type.version Post print en