dc.contributor |
Aalto-yliopisto |
fi |
dc.contributor |
Aalto University |
en |
dc.contributor.author |
Saikko, Vesa |
|
dc.date.accessioned |
2019-09-03T13:48:02Z |
|
dc.date.available |
2019-09-03T13:48:02Z |
|
dc.date.issued |
2019-07-15 |
|
dc.identifier.citation |
Saikko , V 2019 , ' Effect of serum dilution fluids on the wear of unirradiated and high dose gamma-irradiated, vitamin E stabilized UHMWPE ' , Wear , vol. 430-431 , pp. 76-80 . https://doi.org/10.1016/j.wear.2019.04.022 |
en |
dc.identifier.issn |
0043-1648 |
|
dc.identifier.issn |
1873-2577 |
|
dc.identifier.other |
PURE UUID: aa48e854-0792-4665-9adc-ace6d41dcd77 |
|
dc.identifier.other |
PURE ITEMURL: https://research.aalto.fi/en/publications/aa48e854-0792-4665-9adc-ace6d41dcd77 |
|
dc.identifier.other |
PURE LINK: http://www.scopus.com/inward/record.url?scp=85064634757&partnerID=8YFLogxK |
|
dc.identifier.other |
PURE FILEURL: https://research.aalto.fi/files/36337658/ENG_Saikko_Vesa_Effect_of_serum_dilution_fluids_Wear.pdf |
|
dc.identifier.uri |
https://aaltodoc.aalto.fi/handle/123456789/40100 |
|
dc.description.abstract |
In orthopaedic tribology, the ISO 14242-1 standard recommends that the serum lubricant is diluted with deionized water (DW). Sometimes, phosphate buffered saline (PBS) is used instead for the dilution. Noncyclic, multidirectional pin-on-disk tests showed that the dilution of alpha calf serum with PBS or phosphate buffer resulted in a 5–40-fold decrease in the wear factor of unirradiated and of vitamin E stabilized, highly crosslinked ultrahigh molecular weight polyethylene (UHMWPE) compared with DW dilution. It appears that the phosphates were mainly responsible for this phenomenon. PBS dilution may result in a substantial underestimation of clinical wear. With 1:1 DW dilution, the mean wear factor of highly crosslinked UHMWPE was 5.7-fold lower than that of unirradiated UHMWPE. |
en |
dc.format.extent |
5 |
|
dc.format.extent |
76-80 |
|
dc.format.mimetype |
application/pdf |
|
dc.language.iso |
en |
en |
dc.publisher |
Elsevier BV |
|
dc.relation.ispartofseries |
Wear |
en |
dc.relation.ispartofseries |
Volume 430-431 |
en |
dc.rights |
openAccess |
en |
dc.title |
Effect of serum dilution fluids on the wear of unirradiated and high dose gamma-irradiated, vitamin E stabilized UHMWPE |
en |
dc.type |
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä |
fi |
dc.description.version |
Peer reviewed |
en |
dc.contributor.department |
Department of Mechanical Engineering |
|
dc.subject.keyword |
Biomedical devices |
|
dc.subject.keyword |
Lubrication environment |
|
dc.subject.keyword |
Noncyclic pin-on-disk |
|
dc.subject.keyword |
UHMWPE |
|
dc.identifier.urn |
URN:NBN:fi:aalto-201909035142 |
|
dc.identifier.doi |
10.1016/j.wear.2019.04.022 |
|
dc.date.embargo |
info:eu-repo/date/embargoEnd/2021-04-28 |
|