Control strategy for a direct driven hydraulics system in the case of a mining loader

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.author Martinovski, Tatjana
dc.contributor.author Sourander, Tom
dc.contributor.author Turunen, Aleksi
dc.contributor.author Minav, Tatiana
dc.contributor.author Pietola, Matti
dc.contributor.editor Murrenhoff, Hubertus
dc.date.accessioned 2019-02-25T08:55:55Z
dc.date.available 2019-02-25T08:55:55Z
dc.date.issued 2018
dc.identifier.citation Martinovski , T , Sourander , T , Turunen , A , Minav , T & Pietola , M 2018 , Control strategy for a direct driven hydraulics system in the case of a mining loader . in H Murrenhoff (ed.) , 11th International Fluid Power Conference, Aachen, Germany . vol. 1 , RWTH Aachen University , Aachen, Germany , pp. 294-305 , International Fluid Power Conference , Aachen , Germany , 19/03/2018 . https://doi.org/10.18154/RWTH-2018-224472 en
dc.identifier.isbn 978-3-95886-215-9
dc.identifier.other PURE UUID: f6fdebb9-5f90-4da3-b576-194c487d85c2
dc.identifier.other PURE ITEMURL: https://research.aalto.fi/en/publications/control-strategy-for-a-direct-driven-hydraulics-system-in-the-case-of-a-mining-loader(f6fdebb9-5f90-4da3-b576-194c487d85c2).html
dc.identifier.other PURE FILEURL: https://research.aalto.fi/files/31519280/724001_1.pdf
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/36941
dc.description.abstract As a response to the strict government emissions regulations, hybridisation of non-road mobile machinery is required. In this paper, behaviour and efficiency of a hybrid mining loader is studied. The full prototype with implemented DDH (Direct Driven Hydraulics) units had been built; however, its performance was unsatisfactory – a large undershoot and steady-state error of 34 % persisted. Therefore, a new control strategy was suggested to overcome the issues. Performance of the system was enhanced by applying a fuzzy PID controller. As a result, reference tracking was significantly improved compared to the conventional PID control case and steady-state error of 1 % was achieved, while the overall efficiency was kept high in the range of above 50%. en
dc.format.extent 12
dc.format.extent 294-305
dc.format.mimetype application/pdf
dc.language.iso en en
dc.relation.ispartof International Fluid Power Conference en
dc.relation.ispartofseries 11th International Fluid Power Conference, Aachen, Germany en
dc.relation.ispartofseries Volume 1 en
dc.rights openAccess en
dc.subject.other 214 Mechanical engineering en
dc.title Control strategy for a direct driven hydraulics system in the case of a mining loader en
dc.type A4 Artikkeli konferenssijulkaisussa fi
dc.description.version Peer reviewed en
dc.contributor.department Department of Mechanical Engineering
dc.contributor.department Engineering Design
dc.subject.keyword fuzzy control
dc.subject.keyword direct driven hydraulics
dc.subject.keyword mining loader
dc.subject.keyword efficiency
dc.subject.keyword 214 Mechanical engineering
dc.identifier.urn URN:NBN:fi:aalto-201902252098
dc.identifier.doi 10.18154/RWTH-2018-224472
dc.type.version publishedVersion


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search archive


Advanced Search

article-iconSubmit a publication

Browse

My Account