Title: | Feasibility of body electrical loss analysis in detection of abdominal visceral fat BELA-menetelmän soveltuvuus sisäelinrasvan havaitsemiseksi |
Author(s): | Blomqvist, Kim |
Date: | 2018 |
Language: | en |
Pages: | 68 + app. 52 |
Department: | Sähkötekniikan ja automaation laitos Department of Electrical Engineering and Automation |
ISBN: | 978-952-60-8360-5 (electronic) 978-952-60-8359-9 (printed) |
Series: | Aalto University publication series DOCTORAL DISSERTATIONS, 252/2018 |
ISSN: | 1799-4942 (electronic) 1799-4934 (printed) 1799-4934 (ISSN-L) |
Supervising professor(s): | Laakso, Ilkka, Prof., Aalto University, Department of Electrical Engineering and Automation, Finland |
Thesis advisor(s): | Sepponen, Raimo, Prof. Emeritus, Aalto University, Department of Electrical Engineering and Automation, Finland |
Subject: | Medical sciences, Electrical engineering |
Keywords: | body composition, abdominal visceral fat, electrical bioimpedance, BELA, BIA, MRI, kehonkoostumus, sisäelinrasva, bioimpedanssi |
|
|
Abstract:Tavoite: Viskeraalinen eli sisäelinten ympärille kertyvä rasva lisää huomattavasti enemmän terveysriskejä kuin ihonalainen rasva. Diabetekseen ja sydänsairauksiin liitetyn sisäelinrasvan mittaaminen tarkasti yksinkertaisin menetelmin on kuitenkin haastavaa. Yleisesti käytetty painoindeksi (engl. body mass index, BMI) ei tee eroa rasvan jakautumisesta sisäelinrasvan ja ihonalaisen rasvan välillä. Myös täysin normaalipainoinen henkilö voi olla sisäisesti lihava. Tässä työssä kehitettiin uudenlainen kehonkoostumusmittaus-menetelmä, jonka soveltuvuutta viskeraalisen rasvan mittaamisessa tutkittiin magneettikuvantamisen avulla. Menetelmä nimettiin BELA:ksi, mikä tulee englannin kielen sanoista body electrical loss analysis. |
|
Parts:[Publication 1]: Kim H. Blomqvist, Raimo E. Sepponen. A feasibility study of altered spatial distribution of losses induced by eddy currents in body composition analysis. BioMedical Engineering Online, 2010, 9:65, DOI: 10.1186/1475-925X-9-65 View at Publisher [Publication 2]: Kim H. Blomqvist, Jesper Lundbom, Nina Lundbom, Raimo E. Sepponen. Body electrical loss analysis (BELA) in the assessment of visceral fat: a demonstration. BioMedical Engineering Online, 2011, 10:98, DOI: 10.1186/1475-925X-10-98 View at Publisher [Publication 3]: Kim H. Blomqvist, Jussi Kuutti, Jesper Lundbom, Kirsi Pietiläinen, Nina Lundbom, Raimo E. Sepponen. Quantification of visceral adiposity: evaluation of the body electrical loss analysis. Biomedical Physics & Engineering Express, 2018, vol. 4, no. 2, DOI: 10.1088/2057-1976/aaa5bc View at Publisher [Publication 4]: Kim H. Blomqvist, Pekka Eskelinen, Raimo E. Sepponen. Instrumentation amplifier implements second-order active low-pass filter with high gain factor. Measurement Science and Technology, 2011, vol. 22, no. 5, DOI: 10.1088/0957-0233/22/5/057002 View at Publisher [Publication 5]: Kim H. Blomqvist, Raimo E. Sepponen, Nina Lundbom, Jesper Lundbom. An open-source hardware for electrical bioimpedance measurement. In Proc. of 2012 13th Biennial Baltic Electronics Conference (BEC2012), Tallinn, Estonia, October 3–5, pp. 199–202, DOI: 10.1109/BEC.2012.6376851 View at Publisher [Errata file]: Errata of P. 1-3, P. 5 |
|
|
Unless otherwise stated, all rights belong to the author. You may download, display and print this publication for Your own personal use. Commercial use is prohibited.
Page content by: Aalto University Learning Centre | Privacy policy of the service | About this site