Learning Centre

Utilizing data center waste heat in district heating – Impacts on energy efficiency and prospects for low-temperature district heating networks

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.author Wahlroos, Mikko
dc.contributor.author Pärssinen, Matti
dc.contributor.author Manner, Jukka
dc.contributor.author Syri, Sanna
dc.date.accessioned 2017-11-21T13:37:09Z
dc.date.available 2017-11-21T13:37:09Z
dc.date.issued 2017-12-01
dc.identifier.citation Wahlroos , M , Pärssinen , M , Manner , J & Syri , S 2017 , ' Utilizing data center waste heat in district heating – Impacts on energy efficiency and prospects for low-temperature district heating networks ' , Energy , vol. 140 , pp. 1228-1238 . https://doi.org/10.1016/j.energy.2017.08.078 en
dc.identifier.issn 0360-5442
dc.identifier.issn 1873-6785
dc.identifier.other PURE UUID: 83c52eb4-1b89-4940-931c-1e79204d411c
dc.identifier.other PURE ITEMURL: https://research.aalto.fi/en/publications/83c52eb4-1b89-4940-931c-1e79204d411c
dc.identifier.other PURE LINK: http://www.scopus.com/inward/record.url?scp=85029949154&partnerID=8YFLogxK
dc.identifier.other PURE FILEURL: https://research.aalto.fi/files/17305461/1_s2.0_S0360544217314548_main.pdf
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/28817
dc.description.abstract Data centers seek solutions to increase energy efficiency and lower costs by novel methods. Waste heat utilization is considered to be one of the major trends in the near future, especially in the Nordic countries, where heat demand is high. In this paper, waste heat utilization was analyzed from the perspectives of both the data center and district heating network operators. Timing of the data center waste heat production was considered based on an existing data center load profile. For the district heating network operator, the system level effects of increased waste heat utilization were quantified by simulating district heating production in the city of Espoo, Finland, with actual plant and heat demand data for 2013 and 2015. Results showed that with high shares of waste heat in the district heating system, i.e. 20–60 MW, the system level operational cost savings were 0.6–7.3% in the case study. Utilizing waste heat decreased utilization hours of both combined heat and power plants and heat-only boilers. The analysis showed that pricing of the procured waste heat affects the utilization level of waste heat, but operational hours of waste heat utilization were over 95% in all scenarios. en
dc.format.extent 11
dc.format.extent 1228-1238
dc.format.mimetype application/pdf
dc.language.iso en en
dc.relation.ispartofseries Energy en
dc.relation.ispartofseries Volume 140 en
dc.rights openAccess en
dc.title Utilizing data center waste heat in district heating – Impacts on energy efficiency and prospects for low-temperature district heating networks en
dc.type A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä fi
dc.description.version Peer reviewed en
dc.contributor.department Department of Mechanical Engineering
dc.contributor.department Department of Communications and Networking
dc.subject.keyword Data center
dc.subject.keyword District heating
dc.subject.keyword Energy efficiency
dc.subject.keyword Load profile
dc.subject.keyword Waste heat utilization
dc.identifier.urn URN:NBN:fi:aalto-201711217638