Detector alignment studies for the CMS experiment

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.author Lampén, Tapio
dc.date.accessioned 2012-02-24T08:15:07Z
dc.date.available 2012-02-24T08:15:07Z
dc.date.issued 2007-04-20
dc.identifier.isbn 978-952-10-3711-5
dc.identifier.issn 1455-0563
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/2856
dc.description.abstract This thesis presents studies related to track-based alignment for the future CMS experiment at CERN. Excellent geometric alignment is crucial to fully benefit from the outstanding resolution of individual sensors. The large number of sensors makes it difficult in CMS to utilize computationally demanding alignment algorithms. A computationally light alignment algorithm, called the Hits and Impact Points algorithm (HIP), is developed and studied. It is based on minimization of the hit residuals. It can be applied to individual sensors or to composite objects. All six alignment parameters (three translations and three rotations), or their subgroup can be considered. The algorithm is expected to be particularly suitable for the alignment of the innermost part of CMS, the pixel detector, during its early operation, but can be easily utilized to align other parts of CMS also. The HIP algorithm is applied to simulated CMS data and real data measured with a test-beam setup. The simulation studies demonstrate that the algorithm is a promising candidate for the alignment of the pixel detector. The test-beam study shows that the use of the algorithm significantly improves the data measured with genuine CMS hardware. The positioning uncertainties of different parts of CMS have also been systematically estimated. Ready-made scenarios corresponding to these uncertainties have been implemented in the CMS reconstruction software ORCA. These scenarios have been used in the alignment studies. They have also been widely used for more realistic misalignment simulation in the physics performance studies of the CMS collaboration. en
dc.format.extent 46, [50]
dc.format.mimetype application/pdf
dc.language.iso en en
dc.publisher Helsinki University of Technology en
dc.publisher Teknillinen korkeakoulu fi
dc.relation.ispartofseries Internal report / Helsinki Institute of Physics en
dc.relation.ispartofseries 2007-02 en
dc.relation.haspart T. Lampén on behalf of the CMS collaboration, General Alignment Concept of the CMS, Nuclear Instruments and Methods in Physics Research A 566 (2006) 100-103. [article1.pdf] © 2006 Elsevier Science. By permission.
dc.relation.haspart V. Karimäki, T. Lampén, F.-P. Schilling, Track-Based Alignment of Composite Detector Structures, IEEE Transactions on Nuclear Science 53 (6) (2006) 3830-3833. [article2.pdf] © 2006 IEEE. By permission.
dc.relation.haspart V. Karimäki, A. Heikkinen, T. Lampén, T. Lindén, Sensor Alignment by Tracks, in Proceedings of the 2003 Conference for Computing in High Energy and Nuclear Physics, La Jolla, California, USA, eConf C0303241, TULT008, 6 pp. (2003) [arXiv:physics/0306034]. [article3.pdf] © 2003 by authors.
dc.relation.haspart T. Lampén, V. Karimäki, S. Saarinen, O. Buchmüller, Alignment of the Cosmic Rack with the Hits and Impact Points Algorithm, CMS Note 2006/006, CERN, Geneva, Switzerland, 8 pp. (2006). [article4.pdf] © 2006 by authors.
dc.relation.haspart I. Belotelov, O. Buchmüller, I. González Caballero, P. Martínez, C. Martínez-Rivero, F. Matorras, A. Heister, M. Thomas, T. Lampén, V. Valuev, Simulation of Misalignment Scenarios for CMS Tracking Devices, CMS Note 2006/008, CERN, Geneva, Switzerland, 12 pp. (2006). [article5.pdf] © 2006 by authors.
dc.relation.haspart V. Karimäki, T. Lampén, F.-P. Schilling, The HIP Algorithm for Track Based Alignment and its Application to the CMS Pixel Detector, CMS Note 2006/018, CERN, Geneva, Switzerland, 10 pp. (2006). [article6.pdf] © 2006 by authors.
dc.relation.haspart P. Luukka, T. Lampén, L. A. Wendland, S. Czellar, E. Hæggström, J. Härkönen, V. Karimäki, I. Kassamakov, T. Mäenpää, J. Tuominiemi, E. Tuovinen, Test Beam Results of a Proton Irradiated Czochralski Silicon Strip Detector, Nuclear Instruments and Methods in Physics Research A 568 (2006) 72-77. [article7.pdf] © 2006 Elsevier Science. By permission.
dc.subject.other Physics en
dc.subject.other Electrical engineering en
dc.title Detector alignment studies for the CMS experiment en
dc.type G5 Artikkeliväitöskirja fi
dc.description.version reviewed en
dc.contributor.department Department of Engineering Physics and Mathematics en
dc.contributor.department Teknillisen fysiikan ja matematiikan osasto fi
dc.subject.keyword track-based alignment en
dc.subject.keyword HIP en
dc.subject.keyword CMS en
dc.subject.keyword misalignment en
dc.subject.keyword CERN en
dc.subject.keyword position sensitive particle detectors en
dc.identifier.urn urn:nbn:fi:tkk-009143
dc.type.dcmitype text en
dc.type.ontasot Väitöskirja (artikkeli) fi
dc.type.ontasot Doctoral dissertation (article-based) en


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search archive


Advanced Search

article-iconSubmit a publication

Browse

My Account