Learning Centre

Effect of contact area on the wear of ultrahigh molecular weight polyethylene in noncyclic pin-on-disk tests

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.author Saikko, Vesa
dc.date.accessioned 2017-05-31T06:03:46Z
dc.date.available 2017-05-31T06:03:46Z
dc.date.issued 2017-10-01
dc.identifier.citation Saikko , V 2017 , ' Effect of contact area on the wear of ultrahigh molecular weight polyethylene in noncyclic pin-on-disk tests ' , Tribology International , vol. 114 , pp. 84-87 . https://doi.org/10.1016/j.triboint.2017.04.020 en
dc.identifier.issn 0301-679X
dc.identifier.issn 1879-2464
dc.identifier.other PURE UUID: 98b8ddf7-575e-48a5-bf2d-acf7879d4de2
dc.identifier.other PURE ITEMURL: https://research.aalto.fi/en/publications/98b8ddf7-575e-48a5-bf2d-acf7879d4de2
dc.identifier.other PURE LINK: http://www.scopus.com/inward/record.url?scp=85017547383&partnerID=8YFLogxK
dc.identifier.other PURE FILEURL: https://research.aalto.fi/files/13307263/A1_saikko_vesa_2017_3.pdf
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/26527
dc.description.abstract The 16-station RandomPOD pin-on-disk device with non-cyclic biaxial motion and load was used to study the effect of contact area on the wear of ultrahigh molecular weight polyethylene as used in total hip prostheses. The counterface was polished CoCr and the lubricant was diluted serum. The wear factor increased strongly and linearly with increasing contact area, which was in agreement with clinical findings for total hip prostheses. The coefficient of friction also increased strongly with increasing contact area. With small contact area the lumpy topography of the worn surface differed from the burnished appearance typical of retrieved acetabular cups. The nominal contact pressure should be kept below 2 MPa in pin-on-disk tests intended to simulate clinical wear mechanisms. en
dc.format.extent 4
dc.format.extent 84-87
dc.format.mimetype application/pdf
dc.language.iso en en
dc.relation.ispartofseries Tribology International en
dc.relation.ispartofseries Volume 114 en
dc.rights openAccess en
dc.title Effect of contact area on the wear of ultrahigh molecular weight polyethylene in noncyclic pin-on-disk tests en
dc.type A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä fi
dc.description.version Peer reviewed en
dc.contributor.department Department of Mechanical Engineering
dc.subject.keyword Biotribology
dc.subject.keyword Noncyclic pin-on-disk
dc.subject.keyword Prosthetic joint
dc.subject.keyword UHMWPE
dc.identifier.urn URN:NBN:fi:aalto-201705315142
dc.identifier.doi 10.1016/j.triboint.2017.04.020
dc.date.embargo info:eu-repo/date/embargoEnd/2019-04-18


Files in this item

Files Size Format View

There are no open access files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search archive


Advanced Search

article-iconSubmit a publication

Browse

Statistics