Learning Centre

Effect of increased load on the wear of a large diameter metal-on-metal modular hip prosthesis with a high inclination angle of the acetabular cup

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.author Saikko, Vesa
dc.date.accessioned 2017-05-31T06:02:43Z
dc.date.available 2017-05-31T06:02:43Z
dc.date.issued 2016-04-01
dc.identifier.citation Saikko , V 2016 , ' Effect of increased load on the wear of a large diameter metal-on-metal modular hip prosthesis with a high inclination angle of the acetabular cup ' , Tribology International , vol. 96 , no. April , pp. 149-154 . https://doi.org/10.1016/j.triboint.2015.12.032 en
dc.identifier.issn 0301-679X
dc.identifier.issn 1879-2464
dc.identifier.other PURE UUID: 729bfb07-1833-449e-8016-26d0b0856f40
dc.identifier.other PURE ITEMURL: https://research.aalto.fi/en/publications/729bfb07-1833-449e-8016-26d0b0856f40
dc.identifier.other PURE LINK: http://www.scopus.com/inward/record.url?scp=84953923369&partnerID=8YFLogxK
dc.identifier.other PURE FILEURL: https://research.aalto.fi/files/13307389/A1_saikko_vesa_2016.pdf
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/26515
dc.description.abstract In some earlier hip simulator studies of large-diameter metal-on-metal (MoM) hip prostheses high, unexplained variation in wear has been observed. In the present study it was found that high variation occurs when the tribological endurance limit of the MoM device in question is being approached. When the limit is exceeded, high wear takes place uniformly, and the variation is low. Below the limit, both the wear and its variation are low. The endurance limit was exceeded by increasing the peak load from 2 kN to 3 kN, to simulate obesity. The acetabular cup inclination angle was high, 70°. Potential clinical wear problems can be predicted by hip simulator studies provided that relevant adverse test conditions are included. en
dc.format.extent 6
dc.format.extent 149-154
dc.format.mimetype application/pdf
dc.language.iso en en
dc.relation.ispartofseries TRIBOLOGY INTERNATIONAL en
dc.relation.ispartofseries Volume 96, issue April en
dc.rights openAccess en
dc.title Effect of increased load on the wear of a large diameter metal-on-metal modular hip prosthesis with a high inclination angle of the acetabular cup en
dc.type A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä fi
dc.description.version Peer reviewed en
dc.contributor.department Department of Mechanical Engineering
dc.subject.keyword Acetabular cup position
dc.subject.keyword Edge loading
dc.subject.keyword Metal-on-metal
dc.subject.keyword Squeak
dc.identifier.urn URN:NBN:fi:aalto-201705315130
dc.identifier.doi 10.1016/j.triboint.2015.12.032
dc.date.embargo info:eu-repo/date/embargoEnd/2018-01-09