Effect of speed and accuracy of on-line elemental analysis on flotation control performance

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.author Remes, Antti
dc.contributor.author Saloheimo, K.
dc.contributor.author Jämsä-Jounela, Sirkka-Liisa
dc.date.accessioned 2016-09-23T08:24:43Z
dc.date.issued 2007
dc.identifier.citation Remes , A , Saloheimo , K & Jämsä-Jounela , S-L 2007 , ' Effect of speed and accuracy of on-line elemental analysis on flotation control performance ' MINERALS ENGINEERING , vol 20 , no. 11 , pp. 1055-1066 . en
dc.identifier.issn 0892-6875
dc.identifier.issn 1872-9444
dc.identifier.other PURE UUID: df0fa3b1-4ea2-4eee-a4a3-3d4c387c2c3d
dc.identifier.other PURE ITEMURL: https://research.aalto.fi/en/publications/effect-of-speed-and-accuracy-of-online-elemental-analysis-on-flotation-control-performance(df0fa3b1-4ea2-4eee-a4a3-3d4c387c2c3d).html
dc.identifier.other PURE LINK: http://dx.doi.org/10.1016/j.mineng.2007.01.016
dc.identifier.other PURE FILEURL: https://research.aalto.fi/files/6353450/Effect_of_speed_and_accuracy_of_online_elemental_analysis.pdf
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/22368
dc.description.abstract In this paper the control performance of the flotation process is evaluated as a function of the measurement accuracy and sampling frequency of an on-stream analyzer. First, the performance of rule-based control and model predictive control (MPC) strategies is studied using discrete flotation models and the respective performance indices. Next, the net smelter return (NSR) is calculated for varying sampling rate and accuracy combinations using the PI controllers-based control strategy, mechanistic flotation models and the industrial process data as input. The control and economical performance of the process declines strongly when the sampling cycle is increased. The results also indicate that the speed of on-line analysis has a significant effect on the production economics, calculated as the average net smelter return. en
dc.format.extent 1055-1066
dc.format.mimetype application/pdf
dc.language.iso en en
dc.relation.ispartofseries MINERALS ENGINEERING en
dc.relation.ispartofseries Volume 20, issue 11 en
dc.rights openAccess en
dc.title Effect of speed and accuracy of on-line elemental analysis on flotation control performance en
dc.type A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä fi
dc.description.version Peer reviewed en
dc.contributor.department Department of Biotechnology and Chemical Technology en
dc.subject.keyword Flotation; On-stream analysis; Economical optimization; Control performance; Sampling frequency; Measurement accuracy; MPC
dc.subject.keyword Flotation
dc.subject.keyword on-stream analysis
dc.subject.keyword economical optimization
dc.subject.keyword control performance
dc.subject.keyword sampling frequency
dc.subject.keyword measurement accuracy
dc.subject.keyword MPC
dc.identifier.urn URN:NBN:fi:aalto-201609234372