Inductance identification of an induction machine taking load-dependent saturation into account

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.author Ranta, Mikaela
dc.contributor.author Hinkkanen, Marko
dc.contributor.author Luomi, Jorma
dc.date.accessioned 2015-12-10T10:02:20Z
dc.date.available 2015-12-10T10:02:20Z
dc.date.issued 2008
dc.identifier.citation Ranta, Mikaela & Hinkkanen, Marko & Luomi, Jorma. 2008. Inductance identification of an induction machine taking load-dependent saturation into account. 18th International Conference on Electrical Machines, 2008. ICEM 2008. 6. ISBN 978-1-4244-1736-0 (electronic). DOI: 10.1109/icelmach.2008.4799920. en
dc.identifier.isbn 978-1-4244-1736-0 (electronic)
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/18973
dc.description.abstract The paper proposes an identification method for the inductances of induction machines, based on signal injection. Due to magnetic saturation, a saturation-induced saliency appears in the induction motor, and the total leakage inductance estimate depends on the angle of the excitation signal. The proposed identification method is based on a small-signal model that includes the saturation-induced saliency. Because of the saturation, the load also affects the estimate, and measurements are needed in different operating points. Using the identified total leakage inductance, an estimate of the stator inductance can be obtained. The identification method is applied to computer simulations and laboratory experiments of a 2.2-kW induction motor. en
dc.format.extent 6
dc.format.mimetype application/pdf en
dc.language.iso en en
dc.publisher Institute of Electrical & Electronics Engineers (IEEE) en
dc.relation.ispartof 18th International Conference on Electrical Machines, 2008. ICEM 2008 en
dc.rights © 2008 Institute of Electrical & Electronics Engineers (IEEE). Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other work. en
dc.subject.other Automation en
dc.subject.other Electrical engineering en
dc.subject.other Energy en
dc.title Inductance identification of an induction machine taking load-dependent saturation into account en
dc.type A4 Artikkeli konferenssijulkaisussa fi
dc.description.version Peer reviewed en
dc.rights.holder Institute of Electrical & Electronics Engineers (IEEE)
dc.contributor.school Sähkötekniikan korkeakoulu fi
dc.contributor.school School of Electrical Engineering en
dc.contributor.department Sähkötekniikan ja automaation laitos fi
dc.contributor.department Department of Electrical Engineering and Automation en
dc.subject.keyword induction machines en
dc.subject.keyword identification en
dc.subject.keyword inductance en
dc.subject.keyword saturation en
dc.identifier.urn URN:ISBN:978-1-4244-1736-0
dc.type.dcmitype text en
dc.identifier.doi 10.1109/icelmach.2008.4799920
dc.contributor.lab Electric Drives fi