Learning Centre

Manufacture, observation, and test of membranes with locatable single pores

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.author Packard, R. E.
dc.contributor.author Pekola, Jukka P.
dc.contributor.author Price, P. B.
dc.contributor.author Spohr, R. N. R.
dc.contributor.author Westmacott, K. H.
dc.contributor.author Yu-Qun, Zhu
dc.date.accessioned 2015-05-29T09:01:08Z
dc.date.available 2015-05-29T09:01:08Z
dc.date.issued 1986
dc.identifier.citation Packard, R. E. & Pekola, Jukka & Price, P. B. & Spohr, R. N. R. & Westmacott, K. H. & Yu-Qun, Zhu. 1986. Manufacture, observation, and test of membranes with locatable single pores. Review of Scientific Instruments. Volume 57, Issue 8. 1654-1660. ISSN 0034-6748 (printed). DOI: 10.1063/1.1138545. en
dc.identifier.issn 0034-6748 (printed)
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/16395
dc.description.abstract A method for generating single pores down to 0.1 μm diameter in the center of a large circular foil is described, based on nuclear tracks. The foil is framed by a tension ring which enables one to handle the foils in a well‐defined precise way. The single pore has a lateral displacement of ±0.1 mm with respect to the tension ring center. The foils used are polycarbonate of the type Makrofol and have thicknesses between 2 and 10 μm. For calibration of the single pore diameters, multiple nuclear tracks between 0.1 and 3.5 μm diameter are etched and observed by microscopy. The microscopic observations are compared with gas‐flow measurements, using two alternative methods: multiple holes are tested under viscous flow conditions of N2 gas at normal temperature and pressure; single holes are tested under collisionless flow conditions of 4He gas at liquid‐nitrogen temperature, using a capacitance method. en
dc.format.extent 1654-1660
dc.format.mimetype application/pdf en
dc.language.iso en en
dc.publisher AIP Publishing en
dc.relation.ispartofseries Review of Scientific Instruments en
dc.relation.ispartofseries Volume 57, Issue 8
dc.rights © 1986 AIP Publishing. This is the accepted version of the following article: Packard, R. E. & Pekola, Jukka & Price, P. B. & Spohr, R. N. R. & Westmacott, K. H. & Yu-Qun, Zhu. 1986. Manufacture, observation, and test of membranes with locatable single pores. Review of Scientific Instruments. Volume 57, Issue 8. 1654-1660. ISSN 0034-6748 (printed). DOI: 10.1063/1.1138545, which has been published in final form at http://scitation.aip.org/content/aip/journal/rsi/57/8/10.1063/1.1138545 en
dc.subject.other Physics en
dc.title Manufacture, observation, and test of membranes with locatable single pores en
dc.type A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä fi
dc.description.version Peer reviewed en
dc.rights.holder AIP Publishing
dc.contributor.school Perustieteiden korkeakoulu fi
dc.contributor.school School of Science en
dc.contributor.department Department of Applied Physics en
dc.contributor.department Teknillisen fysiikan laitos fi
dc.subject.keyword gas liquid flows en
dc.subject.keyword calibration en
dc.subject.keyword capacitance en
dc.subject.keyword etching en
dc.subject.keyword helium-4 en
dc.identifier.urn URN:NBN:fi:aalto-201505293043
dc.type.dcmitype text en
dc.identifier.doi 10.1063/1.1138545
dc.type.version Final published version en


Files in this item