dc.contributor | Aalto-yliopisto | fi |
dc.contributor | Aalto University | en |
dc.contributor.author | Packard, R. E. | |
dc.contributor.author | Pekola, Jukka P. | |
dc.contributor.author | Price, P. B. | |
dc.contributor.author | Spohr, R. N. R. | |
dc.contributor.author | Westmacott, K. H. | |
dc.contributor.author | Yu-Qun, Zhu | |
dc.date.accessioned | 2015-05-29T09:01:08Z | |
dc.date.available | 2015-05-29T09:01:08Z | |
dc.date.issued | 1986 | |
dc.identifier.citation | Packard, R. E. & Pekola, Jukka & Price, P. B. & Spohr, R. N. R. & Westmacott, K. H. & Yu-Qun, Zhu. 1986. Manufacture, observation, and test of membranes with locatable single pores. Review of Scientific Instruments. Volume 57, Issue 8. 1654-1660. ISSN 0034-6748 (printed). DOI: 10.1063/1.1138545. | en |
dc.identifier.issn | 0034-6748 (printed) | |
dc.identifier.uri | https://aaltodoc.aalto.fi/handle/123456789/16395 | |
dc.description.abstract | A method for generating single pores down to 0.1 μm diameter in the center of a large circular foil is described, based on nuclear tracks. The foil is framed by a tension ring which enables one to handle the foils in a well‐defined precise way. The single pore has a lateral displacement of ±0.1 mm with respect to the tension ring center. The foils used are polycarbonate of the type Makrofol and have thicknesses between 2 and 10 μm. For calibration of the single pore diameters, multiple nuclear tracks between 0.1 and 3.5 μm diameter are etched and observed by microscopy. The microscopic observations are compared with gas‐flow measurements, using two alternative methods: multiple holes are tested under viscous flow conditions of N2 gas at normal temperature and pressure; single holes are tested under collisionless flow conditions of 4He gas at liquid‐nitrogen temperature, using a capacitance method. | en |
dc.format.extent | 1654-1660 | |
dc.format.mimetype | application/pdf | en |
dc.language.iso | en | en |
dc.publisher | AIP Publishing | en |
dc.relation.ispartofseries | Review of Scientific Instruments | en |
dc.relation.ispartofseries | Volume 57, Issue 8 | |
dc.rights | © 1986 AIP Publishing. This is the accepted version of the following article: Packard, R. E. & Pekola, Jukka & Price, P. B. & Spohr, R. N. R. & Westmacott, K. H. & Yu-Qun, Zhu. 1986. Manufacture, observation, and test of membranes with locatable single pores. Review of Scientific Instruments. Volume 57, Issue 8. 1654-1660. ISSN 0034-6748 (printed). DOI: 10.1063/1.1138545, which has been published in final form at http://scitation.aip.org/content/aip/journal/rsi/57/8/10.1063/1.1138545 | en |
dc.subject.other | Physics | en |
dc.title | Manufacture, observation, and test of membranes with locatable single pores | en |
dc.type | A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä | fi |
dc.description.version | Peer reviewed | en |
dc.rights.holder | AIP Publishing | |
dc.contributor.school | Perustieteiden korkeakoulu | fi |
dc.contributor.school | School of Science | en |
dc.contributor.department | Department of Applied Physics | en |
dc.contributor.department | Teknillisen fysiikan laitos | fi |
dc.subject.keyword | gas liquid flows | en |
dc.subject.keyword | calibration | en |
dc.subject.keyword | capacitance | en |
dc.subject.keyword | etching | en |
dc.subject.keyword | helium-4 | en |
dc.identifier.urn | URN:NBN:fi:aalto-201505293043 | |
dc.type.dcmitype | text | en |
dc.identifier.doi | 10.1063/1.1138545 | |
dc.type.version | Final published version | en |
Unless otherwise stated, all rights belong to the author. You may download, display and print this publication for Your own personal use. Commercial use is prohibited.