Aaltodoc - homepage
Communities & Collections
Browse Aaltodoc publication archive
EN | FI |
Log In
  1. Home
  2. Browse by Author

Browsing by Author "Kujala, Juha"

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Communities of practice in implementation of a competence destroying innovation - A case study from the construction industry
    (2009) Kujala, Juha
    Helsinki University of Technology | Master's thesis
    Teknologinen innovaatio, jonka myötä organisaation nykyiset osaamiset ja kyvyt muuttuvat vanhentuneiksi, voidaan määritellä osaamista tuhoavaksi innovaatioksi. Tällaisen innovaation käyttöönotto vaatii uuden osaamisen lisäksi usein myös radikaaleja ja systeemisiä muutoksia työkäytäntöihin ja prosesseihin. Tämä tutkimus tarkastelee osaamisen ja prosessien dynaamista kehittämistä, joka on edellytys teknologisen osaamista tuhoavan innovaation onnistuneelle käyttöönotolle rakennusprojekteissa. Aihetta lähestytään käytäntöyhteisöjen näkökulmasta. Ne ovat vapaamuotoisia ryhmiä, jotka syntyvät ja kehittyvät ihmisten jakamien käytäntöjen ja aihealueiden ympärille. Myös avainhenkilöiden sekä käytäntöyhteisöjen muodostamien konstellaatioiden roolit innovaation käyttöönotossa ovat tutkimuksen kohteina. Tutkimus on konstruktiivinen tapaustutkimus. Ensin nykyisistä teorioista muodostetaan synteesi eli teoriakonstruktio, jota sitten validoidaan ja kehitetään edelleen tapaustutkimuksen avulla. Tapaustutkimus toteutettiin suomalaisessa rakennusalan yrityksessä ja tavoitteena oli tukea GPS-paikannukseen perustuvan työkoneautomaation käyttöönottoa tienrakennusprojekteissa. Tutkimuksen mukaan uusi käytäntöyhteisö voi syntyä pilottiprojektissa, mutta kun useampia pilottiprojekteja käynnistetään, muodostuu käytäntöyhteisöstä vaiheittain projektien välistä oppimista tukeva rakenne. Avainhenkilöt ovat todella tärkeitä käytäntöyhteisön kasvattamisessa, sen yhdistämisessä muuhun organisaatioon, sekä johdon tuen saamisessa yhteisön aloitteille. Radikaali ja systeeminen kehittäminen on mahdollista silloin, kun eri käytäntöyhteisöt tuodaan yhteen konstellaatioon, missä niiden erilaisista näkemyksistä voidaan neuvotella. Tämä voi toteutua esimerkiksi prosessisimuloinnissa, ja voi parhaimmillaan johtaa jopa prosessi-innovaation syntymiseen.
  • No Thumbnail Available
    Development of continuous water content measuring system for process gas
    (2016-04-04) Honkonen, Henri
    Sähkötekniikan korkeakoulu | Master's thesis
    A prototype to continuously measure water content from flue gas was developed and built in this thesis. Two different techniques were theoretically compared for this purpose. Both of which use zirconium-based oxygen sensors. Comparison included measurements based on a wet-dry-oxygen method and a modified UEGO sensor system. The modified UEGO sensor system was preferred and built to the state of prototype. Prototype was designed using a development platform as a starting point and adding necessary electronics to it using daughter boards designed in this thesis. A heated and insulated measurement block was designed to hold two sensors in series. One of the sensors was used to continuously measure direct oxygen concentration and the other was used to decompose water molecules and measure the increase in oxygen level caused by the released oxygen ions in this phenomenon. The phenomenon was created by increasing the reference voltage on the sensor’s electrode form 450 mV to 1080 mV. Tentative performance characteristics of the prototype were tested. It was compared against FTIR- and paramagnetic analyzers that are used as a part of a TÜV-certified CEMS systems. Linear response for O2 was achieved up to 21 % and for H2O up to 40 %. In addition, relative total expanded uncertainty was tested in simplified procedure conforming TÜV-certification tests for both components. This test sequence consisted response time, repeatability standard deviation, lack of fit, short time drift and cross-sensitivity tests. The system passed all the individual tests except span drift test for water content. This was estimated to be mostly because of an unstable reference material. From these tests we calculated the relative total expanded uncertainty UR = 1,3 % for the oxygen over the range 0 – 25 % and UR = 6,1 % for the water content measurement over the range 0 – 40 %.
Help | Open Access publishing | Instructions to convert a file to PDF/A | Errata instructions | Send Feedback
Aalto UniversityPrivacy notice | Cookie settings | Accessibility Statement | Aalto University Learning Centre