Browsing by Author "Ahokas, Jussi"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
- Rakennuksen energiatehokkuutta parantava koneellisesti tuuletettu yläpohjarakenne
School of Engineering | Master's thesis(2012) Ahokas, JussiThis thesis examines roof solution which can reduce heating and cooling energy consumption. Energy is extracted from solar radiation and cool night air. Outdoor air circulation is formed inside the roof structure. Air ventilation tubes goes along the rooftop surface and rotates under heat insulation. Forced air flow intends to increase or reduce heat conductions losses of the roof at those moments when it has an energy-saving effect. Numerical calculation models were used to investigate the effects of structural and climatic changes of structures energy consumption were studied with numerical calculation. Calculations were made in Constanta's climatic conditions. The energy saving effects of the developed structure was studied using energy balance model of the model building. Energy saving calculations was made using Helsinki's and Constanta's climate condition. Energy consumption calculations are approximate, because the climate conditions are simplifications from the real weather data. Simplifications have been made to simplify the modelling methods. The favourable air flow in ventilation tubes for cooling is about 20 m3/m2/h and the flow speed is about 5 m/s, and for heating about 1,3 m/s, when air flow is about 53/m2/h. Concrete is used about 57 kg/m2 at the roof solution. Roof solutions for Helsinki's and the Constanta's climate conditions has different insulation thicknesses. Favourable surface diameter of the ventilation tubes is 1323 mm2. Ventilation tubes are at upper surface approximately in intervals of 109 mm and lower surface in intervals of 218 mm. Benefits of ventilated roof structure dependents on the climatic conditions. The greatest uncertainty in solar heating will cause cloudiness, wind and low outside temperatures. High outside temperatures during night time cooling degrades the cooling power. In Helsinki's weather conditions roof structure can be used for solar heating only in April-May and September-October, and cooling in May-August. In Constanta's weather conditions, the heating season is from October to May and cooling season from June to September. Annual using rate of the ventilation at Helsinki climatic conditions is about 9.5% and at Constanta in about 22.5%. In the research it was found that under Helsinki's climatic conditions can be achieved about 24% savings and under Constanta climatic conditions about 10-11 % savings with the ventilated roof structure compared to the total energy consumption of the model building. The fan control logics of the mechanically ventilated roof structure needs to be improved. High air pressure (120Pa) causes also structural problems, which needs to be solved. The feasibility of the structure and construction costs also requires further research. Roof structures operations should be studied next with model building in real weather conditions. - Nordean henkilöasiakkaiden verkkopankin kehitys Suomessa vuosina 1982-1997 monitasoisen analyysimallin näkökulmasta
School of Economics | Master's thesis(2010) Ahokas, JussiTUTKIMUKSEN TAVOITTEET Tutkimuksen tavoitteena on tarkastella Nordean verkkopankin kehitystä monitasoisen analyysimallin avulla, jonka tarkoituksena on huomioida verkkopankin kehityksen kannalta oleellisia organisaatio-, toimiala- ja yhteiskuntasoilla tapahtuneita muutoksia vuosien 1982 - 1997 välisenä aikana ja pyrkiä identifioimaan näiden tasojen välisiä dynaamisia vuorovaikutussuhteita, joilla on ollut merkitystä verkkopankin kehityksen kannalta. Pyrin näin tuomaan uuden näkökulman verkkopankin kehityksen tarkasteluun ja samalla selvittämään, kuinka hyvin tutkimuksessa käytetty monitasoinen analyysimalli soveltuu innovaatioiden kehitysprosessien tutkimiseen. TUTKIMUKSEN TOTEUTUSTAPA Tutkimuksen teoreettisena viitekehyksenä käytetään sovellettua versiota laajojen sosio-teknisten siirtymien tutkimiseen kehitetystä monitasoisesta analyysimallista. Tutkimusmenetelmänä käytetään historiallista tapaustutkimusta, jonka avulla verkkopankin kehitystä tarkastellaan monitasoisen analyysimallin kolmen tason kautta. Tapaustutkimuksen aineisto perustuu organisaatiotason kehityksen osalta pääasiassa seitsemän Nordean verkkopankkia tutkimusajanjaksolla kehittämässä olleen henkilön teemahaastatteluun. Toimiala- ja yhteiskuntatason aineisto perustuu tutkimuksen perusteella valikoituneeseen aiheesta kirjoitettuun sekundaariaineistoon. TUTKIMUKSEN TULOKSET Tutkimus osoittaa, että monet verkkopankin kehityksen kannalta oleellisista innovaatioista tehtiin jo 1980-luvun alkupuolella, mutta sen aikaiset toimiala- ja yhteiskuntatason tekijät eivät vielä mahdollistaneet itsepalveluiden laajempaa kasvua. 1990-luvun vaihteessa tapahtuneet mullistukset yhteiskunta- ja toimialatasolla antoivat alkusykäyksen itsepalveluiden merkityksen kasvulle ja lopulta Internetin kaupallistuminen 1990-luvun puolivälissä loi mahdollisuuksien ikkunan verkkopankin räjähdysmäiselle kasvulle. Tutkimuksen perusteella monitasoinen analyysimalli soveltuu ainakin verkkopankin kehitystarinan tapauksessa hyvin innovaatioiden kehitysprosessien tutkimiseen. - Projektiliiketoiminnan erityispiirteet verrattuna prosessimaiseen liiketoimintaan
Insinööritieteiden ja arkkitehtuurin tiedekunta | Bachelor's thesis(2008) Ahokas, Jussi